Technical parameters:
1. Power supply: DC 24V
2. Explosion-proof type: Exd Ⅱ CT6
3. Signal output: 4 -- 20 mA standard signal
4. Wiring mode: Three-wire, two-wire (optional)
5. Relay output: Load capacity AC 220V 5A
6. Gas type measured: Combustible gas, toxic gas, oxygen (optional)
7. Measurement range: Combustible gas: 0 -- 100% LEL; oxygen: 0 -- 30% vol; toxic gas: 0 -- 2000 ppm
8. Indication error: Relative error less than 5%
9. Repeatability: < 2%
10. Response time: < 30 sec.
11. Span drift: < 5%
12. Operating environment: Temperature: 0 -- 40℃; relative humidity < 85%
Product Name | Gas Detected | Technical Indicators | ||
Measurement Range | Resolution | First-stage Alarm Value | ||
O2 Detector | O2 | 0~30% vol | 0.1% vol | 18% vol |
H2 Detector | H2 | 0~1000 ppm | 1 ppm | 35 ppm |
NH3 Detector | NH3 | 0~200 ppm | 1 ppm | 25 ppm |
H2S Detector | H2S | 0~100 ppm | 1 ppm | 10 ppm |
CO Detector | CO | 0~2000 ppm | 1 ppm | 50 ppm |
SO2 Detector | SO2 | 0~100 ppm | 0.1 ppm | 5 ppm |
Combustible Gas Detector | Ex | 0~100% LEL | 1% LEL | 25% LEL |